Active Filter: Butterworth
(2st order, 12 dB/octave, Highpass)
C=4.7n-10nF
Ra=0.7071/(2*pi*Fc*C)
Rb=1.414/(2*pi*Fc*C)
Units: Rx [Ohm], C [F], Fc [Hz]
Contributor:
Joakim Ögren
Source: ?
Please send any comments to
Joakim Ögren
.